Allergologie, Jahrgang 18 (1995) - November (511 - 517)

Indoor NO2-concentrations in Erfurt homes – development and testing of a strategy for exposure assessment of an epidemiological study
J. Cyrys1, U. Beyer1, J. Witthauer3, J. Heinrich1, H.E. Wichamnn1,2
1 Institut für Epidemiologie, GSF – Forschungszentrum für Umwelt und Gesundheit, Neuherberg, 2 Institut für Medizinische Informationsverarbeitung, Biometrie und Epidemiologie, Ludwig-Maximilians-Universität, München, 3 Außenstelle Raumklimatologie Erfurt, Institut für Arbeits-, Sozial- und Umweltmedizin, Klinikum der Friedrich-Schiller-Universität, Jena

Add to Cart  

 

DOI 10.5414/ALP18511

Abstrakt

The role of indoor pollutants with regard to allergic diseases is still unclear. This applies also to nitrogen dioxide (NO2). NO2 sources are mainly domestic heating, cooking with gas stoves and penetration from the outdoors. To investigate this relationship the exposure to indoor air pollutants has to be quantified using well-defined measuring specifications. To answer epidemiological questions, measurements over an extended period of time are often required. In such cases passive samplers have been used. In our study a passive sampler was used to determine indoor NO2-concentrations. The detection limit for a one-week exposure time was 7 µg/m3. The precision was around 10%. A distinct difference in NO2-concentrations between homes using gas for heating or cooking and homes not using gas was observed. The highest NO2-concentrations in homes using gas were found in the kitchen (average NO2 level 34 µg/m3), and the lowest average NO2-concentrations were found in the bedroom (18 µg/m3). In homes not using gas the kitchen had the lowest NO2 levels. No significant differences were found between mean NO2 values at the 3 different heights (0.7, 1.2, 2.0 meters) from the floor. An additional outdoor measurement determined the indoor/outdoor ratio of the mean NO2-concentrations in Erfurt. The indoor/outdoor ratio of 0.76 was higher compared to that found in other studies, and this needs to be further investigated.

Autoreninformation

Autoren

Abteilungen

  • 1 Institut für Epidemiologie, GSF – Forschungszentrum für Umwelt und Gesundheit, Neuherberg,
  • 2 Institut für Medizinische Informationsverarbeitung, Biometrie und Epidemiologie, Ludwig-Maximilians-Universität, München,
  • 3 Außenstelle Raumklimatologie Erfurt, Institut für Arbeits-, Sozial- und Umweltmedizin, Klinikum der Friedrich-Schiller-Universität, Jena

Adresse

Dr. rer. nat. J. Cyrys, Postfach 1129, D–85758 Oberschleißheim

Log in for Subscribers

Citation

J. Cyrys, U. Beyer, J. Witthauer, J. Heinrich und H.E. Wichamnn. NO2-Konzentrationen in Erfurter Wohnungen – Entwicklung und Erprobung einer Meßstrategie für eine epidemiologische Studie. 1995; 18: 511-517. doi: 10.5414/ALP18511.

###article_not_exists_msg###

Warenkorb Übersicht

Warenkorb Übersicht
Typ Anz Rabatt MwSt Preis
Der Warenkorb ist leer
Ihr Warenkorb