Int. Journal of Clinical Pharmacology and Therapeutics, Volume 47 - February (132 - 140)

A simple high-performance liquid chromatographic method for the determination of diclofenac in human plasma: application to a comparative bioavailability study
H.M. Rigato1, R.A. Moreno2,3, E.Z. Orpinelli3, B.C. Borges4, C.E. Sverdloff2, J. Pedrazzoli Jr.5, N.C. Borges1, 3
1 Department of Medical Clinic, 2 Department of Pharmacology, State University of Campinas, 3 Synchrophar Assessoria e Desenvolvimento de Projetos Clínicos, Campinas, SP, 4 College of Medicine, Pontificia Universidade Católica, Sorocaba, SP, 5 Integrated Unit of Pharmacology and Gastroenterology, Sao Francisco University Medical School, Bragança Paulista/SP, Brazil

Add to Cart  

 

DOI 10.5414/CPP47132

Abstract

A rapid, sensitive and specific method to quantify diclofenac in human plasma using indomethacin as the internal standard (IS) is described. Samples were extracted using protein precipitation protocol and analyzed by high performance liquid chromatography coupled to ultraviolet detection at 276 nm. Chromatography was performed isocratically with a run time of 8.0 min and the retention time observed for diclofenac and IS was 6.0 and 7.0 min, respectively. The calibration curve was linear over the range 50 – 4,000 ng/ml (r2 > 0.9995). The mean recovery of diclofenac ranged from 88.76 to 99.14% and the limit of quantification was 50 ng/ml. Intrabatch precision and accuracy (%CV) of the method ranged from 0.86 to 7.60%, and 99.34 to 103.8%, respectively. Interbatch precision (%CV) and accuracy ranged from 0.26 to 11.4%, and 92.00 to 105.34%, respectively. This HPLC method was used to determine the relative pharmacokinetics of two diclofenac-cholestyramine 140 mg capsule formulations. The study was conducted using an open, randomized and crossover design with a 1-week washout interval. A single 140 mg dose (equivalent to 70 mg of diclofenac) of each formulation was administered to 26 healthy volunteers (13 males and 13 females) and blood samples were obtained over 12-h interval. The geometric mean of diclofenac-cholestyramine/Flotac® ratio was 90.53% for AUC0-12 and 100.22% for Cmax. Since the 90% CI for Cmax and AUCs ratios were all inside the 80 – 125% interval, it was concluded that the diclofenac-cholestyramine test formulation is bioequivalent to Flotac® regarding both the rate and the extent of absorption.

Author Details

Authors

Departments

  • 1 Department of Medical Clinic,
  • 2 Department of Pharmacology, State University of Campinas,
  • 3 Synchrophar Assessoria e Desenvolvimento de Projetos Clínicos, Campinas, SP,
  • 4 College of Medicine, Pontificia Universidade Católica, Sorocaba, SP,
  • 5 Integrated Unit of Pharmacology and Gastroenterology, Sao Francisco University Medical School, Bragança Paulista/SP, Brazil

Address

N. Carter Borges, MD, MSc, PhD; 24 Cesar Bierrenbach Street, Campinas, SP 13015-025, Brazil
Email: [email protected]

Citation

H.M. Rigato, R.A. Moreno, E.Z. Orpinelli, B.C. Borges, C.E. Sverdloff, J. Pedrazzoli Jr. and N.C. Borges, .A simple high-performance liquid chromatographic method for the determination of diclofenac in human plasma: application to a comparative bioavailability study . 2009; 47: 132-140. doi: 10.5414/CPP47132.

###article_not_exists_msg###

Shopping Overview

Shopping Overview
Type Qtty Discount VAT Price
Your basket is empty
View Cart