Clinical Nephrology, Upcoming Articles - N/A (0 - 8)

Analytical validation of an ELISA-based test kit for polymeric IgA immune complexes in IgA nephropathy

Wei Wang1, Qi Bian3, Qing Zhong1,2, Shasha Chen1, Lisha Ma1, Zhiyong Guo3, Aibing Rao4, Jicheng Lv5, Hong Zhang5, Xingfang Xie6, Jing Jin7, Guisen Li1
1 Renal Division and Institute of Nephrology, Sichuan Provincial People’s Hospital, School of Medicine, University of Electronic Science and Technology of China, 2 Department of Nephrology, Chongzhou People’s Hospital, Sichuan, 3 Department of Nephrology, Changhai Hospital, Naval Medical University, Shanghai, 4 Shenzhen Luwei (Biomanifold) Biotechnology Limited, Shenzhen, 5 Renal Division, Peking University First Hospital Peking University Institute of Nephrology Key Laboratory of Renal Disease, Ministry of Health of China Key Laboratory of Chronic Kidney Disease Prevention and Treatment (Peking University), Ministry of Education, Research Units of Diagnosis and Treatment of Immune-mediate Kidney Disease, Chinese Academy of Medical Sciences, Beijing, 6 Department of Nephrology, The First Affiliated Hospital of Medical College, Xi’an Jiaotong University, Xi’an, PR China, and 7 Department of Medicine/Nephrology and Hypertension, Feinberg Cardiovascular and Renal Research Institute, Northwestern University Feinberg, School of Medicine, Chicago, IL, USA

Add to Cart  

 

DOI 10.5414/CN111934

Abstract

Background and objectives: Circulating polymeric IgA immune complexes (Poly-IgA) have been proposed as potential biomarkers for IgA nephropathy (IgAN); however, standardized clinical assays for their detection are not yet available. We developed and analytically validated an ELISA-based test kit for Poly-IgA and evaluated its diagnostic performance in a retrospective, two-center cohort. Materials and methods: Analytical validation of the ELISA kit was performed using samples collected from two independent centers. The validation included evaluation of the linear range, precision, and limit of detection (LOD). Clinical samples comprised healthy controls, patients with IgA nephropathy (IgAN), and patients with non-IgAN kidney diseases (nKD), including membranous nephropathy (MN), focal segmental glomerulosclerosis (FSGS), and other biopsy-confirmed glomerular diseases. Diagnostic sensitivity, specificity, and correlations with routine clinical parameters were evaluated. Results: The test kit demonstrated robust analytical performance, with a limit of blank (LOB) of 10 U/mL, recovery ranging from 85 to 105%, and a linear range of 15.63 – 500 U/mL. Receiver operating characteristic (ROC) curve analysis of retrospective clinical samples yielded an area under the curve (AUC) of 0.87. At an optimal cutoff value of 75.6 U/mL, the assay demonstrated a sensitivity of 82.7%, specificity of 76.0%, and overall diagnostic accuracy of 78.0%. These findings suggest that the assay may serve as a promising diagnostic tool for differentiating IgAN from non-IgAN kidney diseases; however, further validation in larger, multicenter, and more diverse cohorts is warranted. Conclusion: The ELISA-based Poly-IgA test kit was analytically validated and demonstrated good diagnostic performance in differentiating IgAN from nKD in a two-center cohort. Although its specificity of 76% is insufficient to replace kidney biopsy as the diagnostic gold standard, the assay may serve as a promising non-invasive adjunctive tool to support clinical decision-making, particularly for screening and disease monitoring. In light of these limitations, including the relatively small sample size, prospective multicenter studies in larger and more diverse populations are warranted to further establish its clinical utility.


Author Details

Authors

Departments

  • 1 Renal Division and Institute of Nephrology, Sichuan Provincial People’s Hospital, School of Medicine, University of Electronic Science and Technology of China,
  • 2 Department of Nephrology, Chongzhou People’s Hospital, Sichuan,
  • 3 Department of Nephrology, Changhai Hospital, Naval Medical University, Shanghai,
  • 4 Shenzhen Luwei (Biomanifold) Biotechnology Limited, Shenzhen,
  • 5 Renal Division, Peking University First Hospital Peking University Institute of Nephrology Key Laboratory of Renal Disease, Ministry of Health of China Key Laboratory of Chronic Kidney Disease Prevention and Treatment (Peking University), Ministry of Education, Research Units of Diagnosis and Treatment of Immune-mediate Kidney Disease, Chinese Academy of Medical Sciences, Beijing,
  • 6 Department of Nephrology, The First Affiliated Hospital of Medical College, Xi’an Jiaotong University, Xi’an, PR China, and
  • 7 Department of Medicine/Nephrology and Hypertension, Feinberg Cardiovascular and Renal Research Institute, Northwestern University Feinberg, School of Medicine, Chicago, IL, USA

Address

Zhiyong Guo, MD, PhD, Department of Nephrology, Changhai Hospital, Naval Medical University, Shanghai, China; or Guisen Li, MD, PhD, Renal Division and Institute of Nephrology, Sichuan Provincial People’s Hospital, School of Medicine, University of Electronic Science and Technology of China, Sichuan, China,
Email: [email protected]

Log in for Subscribers

Citation

Wei Wang, Qi Bian, Qing Zhong, Shasha Chen, Lisha Ma, Zhiyong Guo, Aibing Rao, Jicheng Lv, Hong Zhang, Xingfang Xie, Jing Jin, and Guisen Li. Analytical validation of an ELISA-based test kit for polymeric IgA immune complexes in IgA nephropathy
. ; : 0-8. doi: 10.5414/CN111934.

###article_not_exists_msg###

Shopping Overview

Shopping Overview
Type Qtty Discount VAT Price
Your basket is empty
View Cart